Note
This parameter takes effect only in the OBKV-HBase mode.
Overview
kv_hbase_client_scanner_timeout_period specifies the timeout period for OBKV-HBase streaming queries.
Privilege requirements
Query parameters
The
systenant and all user tenants can query this parameter using theSHOW PARAMETERSstatement or theGV$OB_PARAMETERSview.Modify parameters
Both the
systenant and user tenants can modify this parameter.
Attributes
Attribute |
Description |
|---|---|
| Parameter type | Int |
| Default Value | 60000 |
| Value range | (0, +∞) |
| Modifiable | Yes, you can use the following methods:ALTER SYSTEM SETStatement modification. |
| Whether to restart the OBServer node for the change to take effect | No, the setting takes effect immediately. |
Configuration example
Set the OBKV-HBase streaming query timeout to 6000.
ALTER SYSTEM SET kv_hbase_client_scanner_timeout_period = 6000;
ALTER SYSTEM SET kv_hbase_client_scanner_timeout_period = 6000 TENANT = mysql_tenant;