Overview
diag_syslog_per_error_limit specifies the threshold for the number of DIAG system logs printed per second for each error code. When the number of logs exceeds this threshold, log printing stops.
Privilege requirements
Query parameters
Both the
systenant and all user tenants can query this parameter using theSHOW PARAMETERSstatement or theGV$OB_PARAMETERSview.Modify parameters
Only the
systenant can modify this parameter. User tenants cannot modify it.
Attributes
Attribute |
Description |
|---|---|
| Parameter type | Int |
| Default Value | 200 |
| Value range | 0, +∞) |
| Modifiable | Yes, you can use the following methods:ALTER SYSTEM SETStatement modification. |
| Whether to restart the OBServer node for the change to take effect | No, the setting takes effect immediately. |
Configuration example
Set the threshold for the number of DIAG system logs per second for each error code to 200.
obclient> ALTER SYSTEM SET diag_syslog_per_error_limit= 200;
References